TEST |
METHOD |
RESULTS |
Accelerated
Weathering |
ASTM G 23 |
2000
hours; no effect on texture or integrity,
with very little color fade. |
| e |
ASTM G 53 |
3000
hours; no effect on texture or integrity,
with very little color fade. |
| Bonding
Strength |
ASTM C 297 |
Therm
Systems: 53.0 psi
Adhesive on concrete: 169.7
Adhesive on E.P.S.: 33.1 psi*
Adhesive on Gypsum: 15.6 psi*
*Failure of substrate |
Fire
Hazard (Finish
Coat) |
ASTM
E 84Comparable methods,re UL-723 NFPA
no.4201 |
Flame
Spread UBC Class 1 NFPA Class A-5
Fuel Contribution: 0
Smoke Development: 10 (less than Red Oak) |
| Toxicity |
Burn-Analyze
Emissions |
No
greater than Douglas fir |
| Wind
Driven |
Fed/Spec.
TT-C 555B |
Passes,
equivalent to 98 MPH wind for 24 hours |
Water
Vapor
1) Permeability
2) Transmission |
ASTM C 355 |
Meets
UBC requirements:
1) 12.34 PERMS
2) 4.98 GRAINS/hr./sq. ft. |
| Mildew
Resistance |
MIL STD 810B |
No
growth of mildew |
| Chemical
Resistance |
3
drops of chemical
placed on panels for
24 hours. |
Mineral
spirits: no effect
Ammonia: no effect
Muriatic Acid: slight softening and staining |
Salt
Spray
Resistance |
ASTM B 117 |
624
hours; no change |
| Freeze
Thaw |
Panels
soaked in water at 20 C for 4 days, then placed at -10 C for 2 hours and
20 C for 2 more hours. |
10
cycles; no cracking, crazing, erosion or other
surface defects at 5x magnification. |
| Abrasion
Resistance |
ASTM D 968 |
500
liters sand; slight wear. No deleterious effects |
|
TEST |
METHOD |
RESULTS |
Accelerated
Weathering |
ASTM G 23
ASTM G 23 |
2000
hours; no effect on texture or integrity,
with very little color fade.
3000 hours; no effect on texture or integrity, with
very slight color fade. |
| Wind
Driven Rain |
Fed/Spec.
TT-C 555B |
No
growth of mildew |
Water
Vapor
1) Permeability
2) Transmission
(finish coat) |
ASTM E 96 |
Meets
UBC requirements:
1) 12.34 PERMS
2) 4.98 GRAINS/hr./sq. ft. |
| Mildew
Resistance |
MIL STD 810C |
No
growth of mildew |
Salt
Spray
Resistance |
ASTM B117 |
624
hours; no change |
| Freeze
Thaw |
Air
dry at 120 F for
minimum 8 hrs.
Water immersion at
70-80 F for 8 hrs and
exposure to -20 F for
minimum 16 hrs. |
10
cycles; no cracking, crazing, erosion or other
surface defects at 5x magnification. |
| Abrasion
Resistance |
ASTM D 968 |
500
liters sand; slight wear. No deleterious effects |
| Chemical
Resistance |
3
drops of chemical
placed on panels for
24 hours. |
Mineral
spirits: no effect
Ammonia: no effect
Muriatic Acid: slight softening and staining |
| Bonding
Strength |
ASTM C 297 |
Therm
Systems: 53.0 psi
Adhesive on concrete: 169.7
Adhesive on E.P.S.: 33.1 psi*
Adhesive on Gypsum: 15.6 psi*
*Failure of substrate |
Thermal
1) Conductivity
2) Resistance
(Finish only) |
Guarded
hot plate
Method. |
1)
K=3.71 BTU/in./sq.ft./F
2) R=0.27 F/hr./sq.ft./BTU |
Thermal
1) Conductivity
2) Resistance
(Insulation Board)
1 lb .ft3 |
ASTM C 177 |
1)
K=0.24 at 40 F 0.26 at 75 F
2) R=4.17 at 40 F 3.85 at 75 F |
Fire
Hazard (Finish
Coat) |
ASTM E 84
Comparable methods,
re UL-723 NFPA
no.4201 |
Flame
Spread UBC Class 1 NFPA Class A-5
Fuel Contribution: 0
Smoke Development: 10 (less than Red Oak) |
| Full
Scale Fire |
Modified
ASTM E 108 |
No contribution to vertical or horizontal flame
spread. |
| Toxicity |
Burn-Analyze
Emissions |
No
greater than Douglas fir |
| Multi-Story
Fire Test |
Southwest
Research
Institute Dept.
Fire Technology
Report #01-8553 |
Meets
requirements of UBC 17-6 |
Fire
Rated Design
Test |
ASTM E119-88 |
The
Pleko Therm System did not affect the fire
ratings |
Water
Resistance of
Coatings |
ASTM D2247-87 |
No
deleterious effects |
| Water
Penetration |
ASTM E 331-86 |
No
water penetration |
BOCA
Radiant Energy
Test |
Nat'l
Bldg.Code 905.2 |
Meets
requirements |
| Full
Scale Vertical Fire |
CAN 4-5101 |
Meets
requirements of National Building code of
Canada |
Multi
Story Fire Test
(Canadian) |
Nat'l Bldg. Code of
Canada Part of
sec.3.1.5.5
|
Meets
requirements of National Building code of
Canada |
| Structural
Performance |
ASTM E330 |
No
separation between system components and no
cracking of exterior Finish. Results as listed above
for all force levels tested (positive and negative) up
to and including points or structure or substrate
failure |
| Impact
Resistant |
EIMA Test Method
E101.86 |
Pleko
standard mesh: Passed 50-89 force inch lbs,
range impact test: Pleko Medium Mesh: Passed
90-150 force in.lbs. range impact test. Pleko High
Impact Armor Mesh with Standard Mesh applied over
it in a second mesh/Base Coat: Passed 300 force
in. lbs. impact test. |
Freeze-Thaw
Resistance
of Exterior Insulation
Finish Systems |
EIMA 101.1 |
No
deleterious effects after 60 cycles |
|
TEST |
METHOD |
RESULTS |
Accelerated
Weathering |
ASTM
G 23 |
2000
hour, No Chalking, cracking, checking, surface erosion or discoloration.
Adhesive qualities unaffected, average bond strength 104 psi. |
| Wind
Driven Rain |
FS-TTC555
B |
After
Exposing the test board to water spray and elevated pressure for 24 hours.
No visible signs of deterioration, no blistering, cracking or wear of finish
coat. |
| Salt
Spray Resistance |
ASTM
B117 |
No
deleterious effect after 300 hours. |
| Freeze
Thaw |
In
accordance with ICBO acceptance criteria |
No
deterioration of finish surface. No cracking, checking, or crazing.
No deterioration effects on bonding properties. |
| Absorption
Freeze Thaw |
ASTM C67-81 |
No
visible damage after 60 cycles. Negligible wt. gain. |
| Mildew
Resistance |
MII STD 810C |
No
growth after 28 days. |
| Abrasion
Resistance |
ASTM D968-81 |
No
cracking, checking or loss of film integrity. |
| Water
Vapor Transmission |
ASTM
E96 Water Method Procedure B |
Pleko
Finish 1.22 grains/HR-FT2 |
| Water
Vapor Transmission (Extruded Polystyrene) |
ASTM
E96 Water Method Procedure B |
One
inch Styrofoam 1.0 gr/HR-FT2 |
| Surface
Burning Characteristics |
ASTM E84 |
Finish:
Flame Spread-5 Smoke Developed-10. |
| Full
Scale Diversified Fire Test |
ASTM E108 |
Prevented
Fire envolvement of core. No vertical or horizontal flame spread. |
| Impact
Resistance |
ASTM E695 30# impact mass |
No
failure, cracking or denting at 180 ft.-lbs. |
| Impact
Resistance |
EIMA 101.86 |
Meets,
exceeds ultra high impact classification (150 in/lbs Exceeds 500 in/lbs)
before failure occurs. |
| Structural
Performance |
ASTM E330 |
No
separation between system components and no cracking of exterior Finish.
Results as listed for all force levels tested (positive and negative) up
to and including points of structure or substrate failure) |
| Multi-Story
Fire Test |
UBC 17-6 |
Meets
Requirements |
| Water
resistance of Coatings |
ASTM 2247-87 |
No
deleterious effects |
| Water
Penetration |
ASTM E 331-86 |
No
Water penetration |
| BOCA
Radiant Energy Test |
Nat'l Bldg. Code 905.2 |
Meets
Requirements |